Skip to main content
Home Not Calibrated For Indicated Only Labels - Blue Labels On A Roll

Not Calibrated For Indicated Only Labels - Blue Labels On A Roll

As Low As £11.90

Not Calibrated For Indicated Only Labels - Blue Labels On A Roll

  • slider-image-0
Item 1 of 2
  • slider-image-0
  • slider-image-1
Item 1 of 2
Image Full

Free Delivery On Orders Over £65*

Image Full

30 Day Guarantee No Quibble Returns

Image Full

£500 Instant Credit For UK Businesses

Image Full

Buy From The Experts Rated Excellent on Trustpilot

Image Full

Customised Products Create your signs and workwear in seconds

As Low As £11.90
Description
Specifications
Regulations
Materials
Applications

Calibration Labels are an easy way of marking tools, equipment and meters to inform users that devices have been correctly tested as safe and suitable for purpose

  • This is vital to ensure that readings on equipment are accurate to prevent product recalls or giving patients inaccurate results in healthcare environments
  • Write-on labels are perfect for identifying instruments, tools, gauges and test equipment within a calibration system
  • Help you to remain ISO 9001 accredited and comply with other quality systems
  • Ideal for use low wear environments such as office blocks and general business premises
  • Larger rolls provide better value for money and ensure supplies are always close to hand
  • Permanent acrylic adhesive with a high initial tack, excellent adhesion and good low temperature performance on a wide variety of internal surfaces
  • Easy to apply - labels come with their own adhesive
  • Labels are suitable for internal use only
Label Type:
Calibration Labels
Label Reads:
Not Calibrated For Indicated Only
Material:
Adhesive Gloss Paper
Pack Qty:
Roll Of 250
How To Order:
Select the Required Size, Material and Quantity then click `Add To Basket`

ISO 9001 & Calibration

When it comes to monitoring and measuring resources under ISO 9001 guidelines, there are certain guidelines that must be strictly adhered to for the most accurate results possible.

Measurement traceability is the process of validating the equipment that will be used to measure products and resources. This is an ISO requirement, and will give the organization confidence that all measurements are completely correct.

The specific standards for measurement traceability are outlined briefly in the list below, and explained more in detail throughout the rest of this section.

Instruments Used for Measurement:

  • Calibrated in intervals before being used (following standards)
  • Adjusted according to manufacturer’s instructions
  • Able to identify calibration status
  • Protected from adjustment that could affect results of measurement
  • Protected from damages during moving, repairs, or storage
  • Non-conforming devices are checked against a conforming device
  • Calibrated by ISO certified providers
  • Calibration and verification records kept and maintained
  • Computer software confirmed and validated before use
  • Computer software re-validated if needed

To begin, the instruments that are used for measuring resources must always be calibrated in intervals before being used, while following the specified standards in doing so. They must also be adjusted according to the instructions as provided by the manufacturer prior to being used to make accurate measurements. In a visible area on the outside of the machine, the operators must be able to clearly identify the status of calibration during these adjustments.

Source: https://www.iso-9001-checklist.co.uk/7.1-monitoring-and-measuring-resources-for-ISO-9001.htm

Gloss White Inkjet Paper

A white, high gloss, coated paper with a highly absorbent surface structure specifically designed for water-based ink jet printing. Gives excellent colour reproduction and bright, vivid colours. The face stock is made from FSC® certified paper.

Adhesive

A clear permanent acrylic pressure sensitive adhesive with a very high level of adhesion, combined with good tack and shear resistance. Also, good resistance to the effect of migration of phthalate plasticiser, UV and oxidisation. The adhesive is characterised by a high initial tack, excellent adhesion and good low temperature performance on a wide variety of substrates.

Approvals

The adhesive complies with the European food directives and legislations, FDA 175.105 and the German recommendations. XIV as published by BfR. BfR (Bundesinstitut für Risikobewertung) is the German Federal Institute for Risk Assesment. The adhesive side may stand in direct contact with dry, moist and such fatty foodstuffs which have a correction factor of at least 3 according to the Regulation (EU) No 10/2011.

Shelf Life

Two years under storage conditions as defined by Premier Coating & Converters Ltd 20° - 28° C and 40 – 60% RH.

Surfaces and Environments

  • Card / Cardboard (Fluted/Coated/Uncoated)
  • Ceramics (Glazed)
  • Clothing (Coarse Weave)
  • Glass
  • Leather
  • Metal (Painted/Powder Coated)
  • Packaging (Foam, Polystyrene & Sponge)
  • Paper (Coated/Uncoated)
  • Plastic (Rigid/Smooth)
  • Resin
  • Rubber (Uncoated)
  • Shell
  • Wood (PAR Finish/Polished)

Performance Data

  • Temperature: Ambient (30ºC - 25ºC)
  • Locations: Internal (Not Weatherproof)
  • Initial Tack: 16 N/25mm / FINAT FTM 9 Glass
  • Peel Adhesion: 90°: 9 N/25mm / FINAT FTM 1
  • Min. Application Temp.: 0° C
  • Service Temperature: -20° C to 80° C
  • Shelf Life: Two years under storage conditions as defined by Premier Coating & Converters Ltd 20° - 28° C and 40 – 60% RH
Prices excludes VAT at 20%

Price List - To order please specify a quantity. Then click the "Add to Basket" button.

XY10190-RL - Not Calibrated For Indicated Only Blue Sticker - 51x25mm (Roll of 250)

Dimensions 51 x 25mm
Material Adhesive Gloss Paper
Pack Qty 250 Stickers
1 - 4 £14.17
5 - 9 £13.34
10 - 19 £12.57
20+ £11.90
Quantity

Calibration Labels are an easy way of marking tools, equipment and meters to inform users that devices have been correctly tested as safe and suitable for purpose

  • This is vital to ensure that readings on equipment are accurate to prevent product recalls or giving patients inaccurate results in healthcare environments
  • Write-on labels are perfect for identifying instruments, tools, gauges and test equipment within a calibration system
  • Help you to remain ISO 9001 accredited and comply with other quality systems