Skip to main content
Home Fire Equipment & Accessories Fire Extinguishers Water Mist Fire Extinguishers Multimist WaterMist Fire Extinguisher - 6Ltr - Rating 13A, 25F - With a FREE Sign!

Multimist WaterMist Fire Extinguisher - 6Ltr - Rating 13A, 25F - With a FREE Sign!

As Low As £64.50

Multimist WaterMist Fire Extinguisher - 6Ltr - Rating 13A, 25F - With a FREE Sign!

  • slider-image-0
Item 1 of 4
Flash-5
  • slider-image-0
  • slider-image-1
  • slider-image-2
Item 1 of 4
Image Full

Free Delivery On Orders Over £65*

Image Full

30 Day Guarantee No Quibble Returns

Image Full

£500 Instant Credit For UK Businesses

Image Full

Buy From The Experts Rated Excellent on Trustpilot

Image Full

Customised Products Create your signs and workwear in seconds

As Low As £64.50

Designed to combat Class A and F fires, plus safe for inadvertent use on electrically started fires. Utilising a specially designed nozzle, this multimist extinguisher generates a fine mist of water droplets with a surface area coverage many times higher than water in its natural state.

  • Offers protection against class A and F fires with fire ratings of 13A and 25F.
  • Deprives fires of oxygen and heat: droplets turn to steam on contact with fire to envolope flames.
  • Environmentally friendly protection with no harmful chemicals or synthetics, resulting in minimal collateral damage
  • 6L capacity is easy to manoeuvre and deploy
  • Easy, ergonimic squeeze grip operation with additional valve control to temporarily interrupt extinguishing if required
  • Robust construction: features corrosion and UV resistant finish to help stand the test of time.
  • Quality assured: BSI Kitemarked to BS EN3 and manufactured to Safety Directive PED/2014/68/UE
  • Integrated mist spray nozzle is easy to use and highly effective in stopping fires
  • Can be refilled multiple times and is conducive to economical service and maintenance
  • Supplied with a 5 year guarantee
  • Exceptional value for money with FREE accessories – buy with VSafety and receive a FREE extinguisher ID sign with every extinguisher purchased to help meet fire safety obligations on your premises.
Prices excludes VAT at 20%

Price List - To order please specify a quantity. Then click the "Add to Basket" button.

AEC8922 - Multimist WaterMist Fire Extinguisher - 6Ltr - WITH FREE SIGN

Description Multimist Watermist Extinguisher
Dimensions 532 x 160mm
Type Water
Weight 9.2kg
Fire Rating 13A/25F
1+ £64.50
Quantity
Specifications
Buying Guide
FAQs
Description FIRECHIEF MULTIMIST 6L WATERMIST EXTINGUISHER
Capacity (L) 6L
Fire Rating 13A/25F
Discharge Time (secs) 9
Working Pressure (bar) 15
Temperature Range (ºC) +5°C-+60°C
Product Height (mm) 532
Product Diameter (mm) 160
Filled Weight (kg)* 9.2
Carton Height (mm) 510
Carton Length (mm) 180
Carton Width (mm) 180
Packaged Weight (kg)** 9.6
Product EAN 5055377962104

Wondering which fire extinguisher you need?

Our Fire Extinguisher buying guide has a wealth of information to help you decide which fire extinguishers you need to meet your fire safety obligations, along with guidance on fire safety regulations, fire extinguisher maintenance and installation. Remember, all fire extinguishers are provided with a corresponding Extinguisher ID sign for FREE!

How Can This Extinguisher Be Identified?

Water and watermist extinguishers feature red labelling. It is critical that each fire extinguisher can be quickly and clearly identified in the event of a fire. That's why we provide a quality Fire Extinguisher ID sign FREE with every extinguisher to help you meet obligations more easily and for less cost.

What Is A Watermist Extinguisher?

Utilising a specially designed nozzle, the multimist extinguisher generates a fine mist of water molecules. These tiny ‘water mist’ droplets have a surface area coverage many times higher than water in its natural state. The principle is simple: the smaller the particles of water, the further they spread and the faster they cool. On contact with the flames, the water mist turns into steam and envelopes the fire. This blanket effect cools the blaze down and brings the oxygen supply to below combustion levels. Without oxygen or heat, the fire dies out and because this isn’t water in its natural state, the dangers of electrocution and flooding are eliminated. This powerful, reliable, efficient extinguisher can be used on different classes of fire and what’s more, since no synthetics or chemicals are used in the process, multimist causes minimal collateral damage.

What Type Of Fire Can This Be Used On?

It is designed to combat Class A and Class F fires and is safe for inadvertent use on electrically started fires. Class A fires are caused by flammable solids, such as plastics, wood, paper, straw, coal, textiles, furniture, etc. Most of these materials are organic or referred to as ‘carbonaceous materials’. Class A fires are common in a variety of settings and they can spread quickly if there are enough combustible materials, oxygen, and heat to sustain the fire. Commercial and industrial premises typically contain a large number of common combustibles, so preventing Class A fires requires knowledge, vigilance, and regular inspection of premises to ensure fire hazards are minimised.

Class F fires are fires which involve cooking oil or fat. Though technically a sub-class of fires caused by flammable liquids or gases, they differ from conventional fires due to the extremely high temperatures involved.

What Is The Lifespan Of A Fire Extinguisher?

UK fire safety regulations suggest that fire extinguishers should be replaced or undergo an extended service every 5 years. However, there are conditions to this. Fire extinguishers must have been well-maintained and fully operational. This includes conducting monthly visual checks and an annual inspection by a qualified fire extinguisher engineer. No extinguisher should exceed 20 years in use. If the fire extinguisher is damaged or in any way not fit for use, it needs to be serviced or replaced immediately. The same applies if it has been discharged; it must be replaced without delay.

How Often Should I Inspect A Fire Extinguisher?

Monthly Fire Extinguisher Inspections

Each month, you should conduct a visual inspection of your fire extinguishers. Here's what to look for:

  • Signs of damage such as corrosion or leakage, or evidence that the fire extinguisher has been interfered with.
  • Issues with the hose or nozzle, such as cracks, blockages, or tears
  • Absent or broken locking pins, seals, and tamper indicators
  • A damaged or loose handle
  • A missing service label. Ensure all labels and tags on fire extinguishers are readable and if the last service was over a year ago, arrange one immediately.
  • Don't forget to document your monthly checks
  • Ensure the pressure gauge is in the green zone and lift the extinguisher to make sure it feels full
  • Check that fire extinguishers are easily visible, not blocked, and the operating instructions are clean and facing outwards. You should also check they are clearly signposted and accessible

Annual fire extinguisher inspections

A qualified fire extinguisher engineer should conduct an annual fire extinguisher inspection. They’ll conduct a full maintenance check with detailed examination, and, if necessary, carry out repairs in line with the Regulatory Reform (Fire Safety) Order 2005 and BS5306 guidelines. After passing its annual service, the fire extinguisher will be tagged and dated. If the extinguisher cannot be adequately repaired so it is in good working order, it must be replaced.

Note that a competent fire extinguisher engineer will not only service the equipment but also assess its placement to ensure it's still correctly positioned and installed on its stand. They will evaluate how fire extinguishers are arranged and whether that's still suitable for the hazards in that area. It's recommended to engage a BAFE registered engineer for your fire extinguisher inspection. BAFE is the independent certification registration organisation for the fire protection industry, and they validate a business's ability to provide fire protection services. This way, you can be sure the engineer is fully competent and meets all the relevant standards.

Remember, it is a legal requirement to keep records of all fire extinguisher inspections, servicing, and maintenance.

In addition to maintaining extinguishers, you should ensure that your fire risk assessment is up to date, with no unresolved actions from your most recent audit. It's crucial that all employees know about any existing fire safety plans and procedures, including the location of fire extinguishers, escape routes, and assembly points. Regular fire drills and fire alarm tests should be conducted to ensure staff are familiar with escape paths and their specific roles. You should regularly check your fire and emergency safety signs to ensure all are present, correct and offering sufficient guidance.

Every workplace will have its unique set of fire safety measures and plans, all employees and visitors should be clear on what to do in the event of a fire on your premises.