Skip to main content
We would like to wish you a very Merry Christmas and a Happy New Year!!
Click Here for Christmas Delivery Times

Please note our offices and warehouses will be closed from 24th December until 2nd January 2025.

In-stock orders placed before 4:30pm on Friday 20th December should arrive before Christmas on a Next Working Day Delivery service. We are unable to guarantee this, however, as we rely on external couriers. Orders placed after this time will be processed and despatched as normal, but we cannot guarantee a pre-Christmas delivery. Any orders placed on Tuesday 24th December, or during the festive period, will be delivered in the first working days of the new year.

We recommend you place your order early, and look forward to serving you again in 2025.

Home Fire Equipment & Accessories Fire Extinguishers Powder Extinguishers Stored Pressure ABC Powder Extinguisher - 6kg - Ratings 27A, 183B, C - With a FREE Sign!

Stored Pressure ABC Powder Extinguisher - 6kg - Ratings 27A, 183B, C - With a FREE Sign!

As Low As £64.95

Stored Pressure ABC Powder Extinguisher - 6kg - Ratings 27A, 183B, C - With a FREE Sign!

  • slider-image-0
Item 1 of 3
Flash-5
  • slider-image-0
  • slider-image-1
  • slider-image-2
Item 1 of 3
Image Full

Free Delivery On Orders Over £65*

Image Full

30 Day Guarantee No Quibble Returns

Image Full

£500 Instant Credit For UK Businesses

Image Full

Buy From The Experts Rated Excellent on Trustpilot

Image Full

Customised Products Create your signs and workwear in seconds

As Low As £64.95

A high quality UK made 6kg stored pressure ABC powder fire extinguisher. Suitable for use on Class A fires (solid materials), Class B fires (flammable liquids or liquefiable solids) and Class C fires (flammable gases), making them ideal for use in environments containing multiple fire risks. It is highly effective against petrol and volatile liquids which also makes them suitable for larger vehicle protection.

  • Multi-purpose application: Offers protection against class A, B and C type fires with fire ratings of 27A, 183B and C.
  • 6kg capacity is easy to manoeuvre and deploy whilst offering 16 seconds of discharge time.
  • Squeeze grip operation for ease of use when it matters most
  • Robust construction: features internal polyethylene lining and corrosion resistant finish to help stand the test of time.
  • High quality construction features a deep-drawn cylinder and heavy duty brass valves
  • Supplied complete with distinctive colour coded header label, handle and base which ensure that the extinguisher is identifiable from any angle. This can provide valuable and critical time when helping to evacuate a building or extinguish a small fire, if safe to do so.
  • Quality assured: BSI Kitemark certified to BS EN3, UKCA and CE marked
  • UK made by an accredited 'Made In Britain' manufacturer
  • Supplied with a 5 year guarantee
  • Exceptional value for money with FREE accessories – buy with VSafety and receive a FREE colour coded base and FREE extinguisher ID sign with every extinguisher purchased to help meet fire safety obligations on your premises.
Prices excludes VAT at 20%

Price List - To order please specify a quantity. Then click the "Add to Basket" button.

AEC8941 - Store Pressure ABC Powder Fire Extinguisher - 6kg - WITH FREE SIGN

Description ABC Powder Extinguisher
Dimensions 517 x 160mm
Type Powder
Weight 9.55kg
Fire Rating 27A/183B/C
1 - 4 £69.95
5+ £64.95
Quantity
Specifications
Buying Guide
FAQs
Description 6KG ABC POWDER PREMIUM RANGE FIRE EXTINGUISHER
Capacity (L) 6KG
Fire Rating 27A/183B/C
Propellant Nitrogen Gas
Discharge Time (secs) 16.1
Working Pressure (bar) 15
Temperature Range (ºC) -20°C-+60°C
Product Height (mm) 517
Product Diameter (mm) 160
Filled Weight (kg) 9.55
Carton Height (mm) 529
Carton Length (mm) 177
Carton Width (mm) 177

Wondering which fire extinguisher you need?

Our Fire Extinguisher buying guide has a wealth of information to help you decide which fire extinguishers you need to meet your fire safety obligations, along with guidance on fire safety regulations, fire extinguisher maintenance and installation. Remember, all fire extinguishers are provided with a corresponding Extinguisher ID sign for FREE!

How Can This Extinguisher Be Identified?

Powder fire extinguishers feature blue labelling. It is critical that each fire extinguisher can be quickly and clearly identified in the event of a fire. That's why we provide a quality Fire Extinguisher ID sign FREE with every extinguisher to help you meet obligations more easily and for less cost.

What Type Of Fire Can This Be Used On?

This extinguisher can be used on A, B and C class fires making it ideal for extinguishing vehicle fires, as well as electrical hazards, flammable liquids and gasses, and general wood/paper fires. The use of powder fire extinguishers indoors is not recommended by BS 5306-8: 2012 due to the mess powder can create and the potential impairment of vision and respiration it can cause within a confined space.

What Is The Lifespan Of A Fire Extinguisher?

UK fire safety regulations suggest that fire extinguishers should be replaced or undergo an extended service every 5 years. However, there are conditions to this. Fire extinguishers must have been well-maintained and fully operational. This includes conducting monthly visual checks and an annual inspection by a qualified fire extinguisher engineer. No extinguisher should exceed 20 years in use. If the fire extinguisher is damaged or in any way not fit for use, it needs to be serviced or replaced immediately. The same applies if it has been discharged; it must be replaced without delay.

How Often Should I Inspect A Fire Extinguisher?

Monthly Fire Extinguisher Inspections

Each month, you should conduct a visual inspection of your fire extinguishers. Here's what to look for:

  • Signs of damage such as corrosion or leakage, or evidence that the fire extinguisher has been interfered with.
  • Issues with the hose or nozzle, such as cracks, blockages, or tears
  • Absent or broken locking pins, seals, and tamper indicators
  • A damaged or loose handle
  • A missing service label. Ensure all labels and tags on fire extinguishers are readable and if the last service was over a year ago, arrange one immediately.
  • Don't forget to document your monthly checks
  • Ensure the pressure gauge is in the green zone and lift the extinguisher to make sure it feels full
  • Check that fire extinguishers are easily visible, not blocked, and the operating instructions are clean and facing outwards. You should also check they are clearly signposted and accessible

Annual fire extinguisher inspections

A qualified fire extinguisher engineer should conduct an annual fire extinguisher inspection. They’ll conduct a full maintenance check with detailed examination, and, if necessary, carry out repairs in line with the Regulatory Reform (Fire Safety) Order 2005 and BS5306 guidelines. After passing its annual service, the fire extinguisher will be tagged and dated. If the extinguisher cannot be adequately repaired so it is in good working order, it must be replaced.

Note that a competent fire extinguisher engineer will not only service the equipment but also assess its placement to ensure it's still correctly positioned and installed on its stand. They will evaluate how fire extinguishers are arranged and whether that's still suitable for the hazards in that area. It's recommended to engage a BAFE registered engineer for your fire extinguisher inspection. BAFE is the independent certification registration organisation for the fire protection industry, and they validate a business's ability to provide fire protection services. This way, you can be sure the engineer is fully competent and meets all the relevant standards.

Remember, it is a legal requirement to keep records of all fire extinguisher inspections, servicing, and maintenance.

In addition to maintaining extinguishers, you should ensure that your fire risk assessment is up to date, with no unresolved actions from your most recent audit. It's crucial that all employees know about any existing fire safety plans and procedures, including the location of fire extinguishers, escape routes, and assembly points. Regular fire drills and fire alarm tests should be conducted to ensure staff are familiar with escape paths and their specific roles. You should regularly check your fire and emergency safety signs to ensure all are present, correct and offering sufficient guidance.

Every workplace will have its unique set of fire safety measures and plans, all employees and visitors should be clear on what to do in the event of a fire on your premises.